"CONSTANT VOLTAGE" TRANSFORMER POWER DELIVERED Back Forward
audio R
stage Lvideo Lpro-audio Lvideo Lfixture Laudio Lvideo Llighting Llighting L Alpha Sound & Lighting Co.'s Resource Toolsvideo projection divider
Alpha Question & Answers
Question & Answers Are you ready for your system installation? Review our System Installation Check List to verify system requirements... video bar
stage lighting divider
Pro-Audio Stage Lighting Video Projection
Pro-Audio / Stage Lighting / Video Projection
Learn About Alpha's Services
light column 1light column 2light column 3light column 4light column 5light column 6light column 7light column 8light column 8
CONSTANT VOLTAGE CALCULATOR - COPYRIGHT CROWN®
Many people don't realize that a transformer labeled for use with a specific voltage will work just as well at other voltages. This calculator provides power delivered from a transformer tap when driven with other than the rated voltage. This tool is useful when designing audio systems with various amplifiers. This Javascript calculator requires Microsoft Internet Explorer v4.0+ or Mozilla Firefox v1+ browser.
audio / lighting / video bar
Voltage Rating of Transformer Tap Rating
 volts  watts
New Voltage Power from Tap
 volts watts
 
audio / lighting / video bar
EXAMPLE: You are installing a distributed system with very long lines. To overcome line loss, you select a 140 volt system. Which transformer tap will feed 10 watts to a loudspeaker with a "70V transformer?
• 1. Enter values for both "Voltage Rating of Transformer" and "New Voltage"
• 2. Either:
•• Enter a value for "Tap Rating" to calculate the power output from the tap at the new voltage.
•• Enter a value for "Power from Tap" to calculate the correct transformer tap to achieve the desired power at the new voltage.
audio / lighting / video bar
EQUATION USED TO CALCULATE THE DATA:
Pactual = (Vnew squared / Vrated squared) * Prated
WHERE:
Prated = transformer tap value
Pactual = new power from tap
Vrated = voltage rating of transformer
Vnew = new voltage
audio / lighting / video bar
stage Rvideo Rpro-audio Rvideo Rfixture Raudio Rvideo Rlighting Rlighting R
audio L pro-audio divider bar 0 pro-audio divider bar 1 pro-audio divider bar 2 pro-audio divider bar 3
lighting L
Featured Product Learn the Fundamentals of Audio and Acoustics
light column 9
lighting R
video L
Web Forum View Alpha's Discussion Board to read and write about your own system installations...
light column 10
video R
sound corner L sound bar pro-audio sound bar 1 stage lighting bar sound corner R
Alpha Sound & Lighting Co. is a Pro-Audio, Stage Lighting, and Video Projection Company based in Satsuma, Alabama specializing in Church Sound System Design, Consultation, Installation, and Integration. / 174 Baldwin Road Satsuma, AL 36572 / Tel: 251-675-3358 / Fax: 251-675-7572 / Email: info@aslgc.com / This electronic publication is produced by ALPHA SOUND & LIGHTING CO. and no responsibility for errors and omissions is assumed. / All rights reserved. / ©2006 Alpha Sound & Lighting Co. / Webmaster